Balancing instrument TA-SCOPE is a tough, effective balancing instrument for measuring and documenting of differential pressure, flow, temperature and power in hydronic systems. Robust, accurate and easy-to-use, TA-SCOPE delivers quicker, more cost-efficient balancing and enables rapid troubleshooting. TA-SCOPE links effortlessly to the HySelect PC software gaining the maximum benefit from recorded data and enabling professional report writing and automatic software upgrades.
Manufacturer: IMI TA

TA-SCOPE

Balancing instrument TA-SCOPE is a tough, effective balancing instrument for measuring and documenting of differential pressure, flow, temperature and power in hydronic systems. Robust, accurate and easy-to-use, TA-SCOPE delivers quicker, more cost-efficient balancing and enables rapid troubleshooting. TA-SCOPE links effortlessly to the HySelect PC software gaining the maximum benefit from recorded data and enabling professional report writing and automatic software upgrades.

Benefits & Features

User-friendly design

Ergonomic and custom designed user-interface ensures easy and more comfortable balancing.

Interactive software

Step by step software wizards for measuring, balancing and trouble shooting ensure a fast commissioning process.

Wireless communication

For reliable balancing, a fully charged TA-SCOPE provides three days of power-efficient wireless performance.

DpS-Visio

The Dp Sensor has an OLED display for showing Dp measurement, temperature and status. It also has an automatic flushing and calibration function.

Technical Info

Functions:

TA-SCOPE is a balancing instrument for measuring and documenting of differential pressure (Δp), flow, temperature and power in hydronic systems.

TA-SCOPE consists of two main components:
Handheld unit – computer-based unit programmed with the IMI TA valve characteristics. Straightforward functions with easy-to-follow instructions on the colour display.
Differential Pressure Sensor unit – the DpS-Visio communicates wirelessly with the Handheld and has an OLED display for showing its status, measured data and other information. 

TA-SCOPE automatically performs calibration when needed. The design of the sensor unit and a short flow-through during calibration eliminate measurement errors caused by insufficient venting of the measuring device.

Measurement range:

Total pressure:
TA-SCOPE max. 232 psi
TA-SCOPE HP max. 362 psi
Differential pressure:
TA-SCOPE 0 - 72.5 psi
TA-SCOPE HP 0 - 145 psi
Recommended pressure range during flow measurements:
TA-SCOPE 0.02 - 72.5 psi
TA-SCOPE HP 0.5 - 145 psi

Temperature liquid medium measurement:

-4°F – +248°F

Measurement deviation:

Differential pressure: 
TA-SCOPE 0.015 psi or 1% of reading, whichever is the highest
TA-SCOPE HP 0.029 psi or 1% of reading, whichever is the highest
Flow: as for differential pressure + valve deviation
Temperature: <0.36°F

Battery capacity, operating and charge times:

Handheld unit:
- battery capacity: 4 400 mAh
- operating time (with backlight on): >25 h
- charge time to full capacity: 6-7 h
DpS-Visio (Dp sensor unit):
- battery capacity: 1 400 mAh
- operating time (continuous measurements): >25 h
- charge time to full capacity: 2.5 h
Logging time (in sleep mode): >100 days

Ingress protection:

Handheld unit (in wireless mode): IP64
Dp sensor unit (in wireless mode): IP64
Safety pressure and temperature probe: IP65
Digital temperature sensor: IP65

Ambient temperature for the instrument:

During operation and charging: +32 – +104°F
During storage*: -4 – +150°F
*) Do not leave water in the sensor when there is a risk of freezing.

Humidity:

Ambient humidity: max. 90%RH

Charger:

Output voltage: 5.2 V DC (minimum 5.0 V, maximum 5.3 V).
Output current: Minimum 1 A.
Isolation: Class II.
Certification: IEC (868 MHz) and/or UL, CSA (915 MHz).
Complying with the LPS (Low Power Source) regulation.

Case dimensions:

TA-SCOPE Premium case: 
LxWxH = 16.9x11.2x6.69 in
TA-SCOPE case: 
LxWxH = 12.8x10.0x6.50 in

 

Technote Download

CLICK HERE TO DOWNLOAD FULL SPECIFICATIONS OF THIS PRODUCT. 

TA-SCOPE

Balancing instrument TA-SCOPE is a tough, effective balancing instrument for measuring and documenting of differential pressure, flow, temperature and power in hydronic systems. Robust, accurate and easy-to-use, TA-SCOPE delivers quicker, more cost-efficient balancing and enables rapid troubleshooting. TA-SCOPE links effortlessly to the HySelect PC software gaining the maximum benefit from recorded data and enabling professional report writing and automatic software upgrades.

Benefits & Features

User-friendly design

Ergonomic and custom designed user-interface ensures easy and more comfortable balancing.

Interactive software

Step by step software wizards for measuring, balancing and trouble shooting ensure a fast commissioning process.

Wireless communication

For reliable balancing, a fully charged TA-SCOPE provides three days of power-efficient wireless performance.

DpS-Visio

The Dp Sensor has an OLED display for showing Dp measurement, temperature and status. It also has an automatic flushing and calibration function.

Technical Info

Functions:

TA-SCOPE is a balancing instrument for measuring and documenting of differential pressure (Δp), flow, temperature and power in hydronic systems.

TA-SCOPE consists of two main components:
Handheld unit – computer-based unit programmed with the IMI TA valve characteristics. Straightforward functions with easy-to-follow instructions on the colour display.
Differential Pressure Sensor unit – the DpS-Visio communicates wirelessly with the Handheld and has an OLED display for showing its status, measured data and other information. 

TA-SCOPE automatically performs calibration when needed. The design of the sensor unit and a short flow-through during calibration eliminate measurement errors caused by insufficient venting of the measuring device.

Measurement range:

Total pressure:
TA-SCOPE max. 232 psi
TA-SCOPE HP max. 362 psi
Differential pressure:
TA-SCOPE 0 - 72.5 psi
TA-SCOPE HP 0 - 145 psi
Recommended pressure range during flow measurements:
TA-SCOPE 0.02 - 72.5 psi
TA-SCOPE HP 0.5 - 145 psi

Temperature liquid medium measurement:

-4°F – +248°F

Measurement deviation:

Differential pressure: 
TA-SCOPE 0.015 psi or 1% of reading, whichever is the highest
TA-SCOPE HP 0.029 psi or 1% of reading, whichever is the highest
Flow: as for differential pressure + valve deviation
Temperature: <0.36°F

Battery capacity, operating and charge times:

Handheld unit:
- battery capacity: 4 400 mAh
- operating time (with backlight on): >25 h
- charge time to full capacity: 6-7 h
DpS-Visio (Dp sensor unit):
- battery capacity: 1 400 mAh
- operating time (continuous measurements): >25 h
- charge time to full capacity: 2.5 h
Logging time (in sleep mode): >100 days

Ingress protection:

Handheld unit (in wireless mode): IP64
Dp sensor unit (in wireless mode): IP64
Safety pressure and temperature probe: IP65
Digital temperature sensor: IP65

Ambient temperature for the instrument:

During operation and charging: +32 – +104°F
During storage*: -4 – +150°F
*) Do not leave water in the sensor when there is a risk of freezing.

Humidity:

Ambient humidity: max. 90%RH

Charger:

Output voltage: 5.2 V DC (minimum 5.0 V, maximum 5.3 V).
Output current: Minimum 1 A.
Isolation: Class II.
Certification: IEC (868 MHz) and/or UL, CSA (915 MHz).
Complying with the LPS (Low Power Source) regulation.

Case dimensions:

TA-SCOPE Premium case: 
LxWxH = 16.9x11.2x6.69 in
TA-SCOPE case: 
LxWxH = 12.8x10.0x6.50 in

 